An Ozone Air Monitor is a precision instrument designed to measure ozone concentrations in air in real time, ensuring safety, process control, and environmental compliance in various settings where ozone is present or generated. Ozone (O₃) — a tri-atomic form of oxygen — is widely used as a powerful oxidizing and disinfection agent, but at elevated levels it can be harmful if inhaled. Monitoring ozone levels helps in managing ventilation systems, safe operation of ozone generators, industrial hygiene, and indoor/outdoor air quality assessment. Ozone air monitors are employed in industrial facilities, environmental monitoring networks, HVAC systems, laboratories, and any application where ozone exposure and regulation are concerns.
How Ozone Air Monitors Work
Ozone air monitors use advanced sensing methods to detect and quantify ozone in the air:
Real-Time & Continuous Monitoring
Most ozone air monitors are designed for continuous, real-time detection, often with digital displays and data outputs (e.g., 4-20 mA, RS-485, or USB) for connection to control systems, building management systems (BMS), or industrial automation setups. They can also support alarms, data logging, and remote transmission for enhanced safety and compliance.
Measurement Ranges & Sensitivity
Ozone air monitors can detect a wide range of concentrations — from low parts-per-billion (ppb) levels suitable for air quality and environmental monitoring to higher parts-per-million (ppm) ranges relevant for industrial safety and ozone-generation applications.
Ozone air monitors are available in both fixed units for facility monitoring and portable handheld models for spot checks, leak detection, and mobile assessments.
⚠️ Health & Safety Note: Ground-level ozone is a trace gas that can be harmful at elevated concentrations; monitoring helps prevent overexposure and protect respiratory health, especially in indoor or confined industrial environments where ozone generators are operated.
These Single Point Wall Mounted Instruments work on 220 VAC mains supply and have a sensor fitted at the end of a cable. They use an IP 55 enclosure for the electronics as standard. The sensor is located at the site to be monitored and the monitor electronics in a safe area/instrumentation room. They are provided with two alarms both audible and visual along with relays and recorder output of 0-1 v and 4-20 mA. They are meant for continuous operation of area rnonitoring with continuous read out, plus vital status indicators
Applications
Used for continuous surveillance single point monitoring either toxic or flammable gases in work places or enclosed spaces.
Features :
Two alarms audible and visual alongwith acknowledge and reset buttons, both set points viewable from front face
One NO C NC potential free relay contact per alarm
Confidence flash
0-1 V and 4-20 ma recorder output
Alarm and buzzer inhibit switches provided
One alarm high the other settable as Low or High alarm
All connections under cable entry cover through glands
Status indicators for Alarm, alarm acknowledge, Buzzer inhibit, Relay inhibit & Confidence flash
Specifications :
| Gas Detected | Ozone |
| Sensing Element | Electrochemical gas sensor |
| Sensor lifetime | >2 years, removable |
| Temperature Sensor | NTC 5K |
| Humidity Sensor | HS series capacitive sensor |
| Power Supply | 24VAC/VDC (power adaptor selectable) |
| Power Consumption | 2.8W |
| Response Time | <50s @T90 |
| Signal Update | 1s |
| Warm up Time | <60 seconds |
| Ozone Measuring Range | 0~5000ppb (0~5ppm)( 0~9.81mg/m³ ) |
| Display Resolution | 1ppb (0.001ppm) (0.01mg/m³) |
| Accuracy | ±0.01ppm + 10% reading |
| Nonlinear | <1%FS |
| Repeatability | <0.5% |
| Zero Drift | <1% |
| Alarm | Buzzer and Yellow or Red backlight switch |
| Display |
Green - normally,
Orange – first stage alarm,
Red – second stage alarm. Ozone alarm points can be preset. |
| Temperature/humidity Measuring Range | 20°C~60°C ( -4°F~140°F )/0~99%RH |
| Analog Output | 0~10VDC(default) or 4~20mA linear output selectable |
| Analog Output Resolution | 16Bit |
| Relay dry contact Output |
Two dry-contact outputs Max, switching current 3A (220VAC/30VDC), resistance Load |
| Modbus Communication Interface |
Modbus RTU protocol with 19200bps(default) Other bps rate selectable in order 15KV antistatic protection |
| Working Condition | 20°C~60°C ( -4°F~140°F )/0~99% RH |
| Storage Conditions | 40°C~-70°C ( -40°F~158°F )/0~95% RH |
| Net Weight | 190g |
| Dimensions | 130mm(H)×85mm(W)×36.5mm(D) |
| Installation Standard | 65mm×65mm or 85mm×85mm or 2"×4" wire box |
| Interface Connection (Max) | 9 terminals |
| Wiring Standard | Wire section area≥1.5mm² |
| Manufacturing Process | ISO 9001 Certified |
| Housing and IP class | PC/ABS fireproof plastic material, protection class: IP30 |
| Compliance | EMC Directive 89/336/EEC |
Specifications :
| Alarms | Latching OR Non-Latching |
| Sensor | On Cable of length to be specified while ordering. Max 50 meters |